Genuine Fisher & Paykel extended life replacement humidifier chamber for HC100, HC105, and HC150 series heated humidifiers. Durable construction with stainless steel base and high-density plastic dome that fully disassembles for thorough cleaning.

The HC300 Extended Life Humidifier Chamber is the durable, long-lasting replacement water chamber for Fisher & Paykel HC100, HC105, and HC150 series heated humidifiers. Designed to last for many years, this chamber is an upgrade from the standard HC325 water chamber that comes with the HC100/150 heated humidifier.

Built with sturdier materials than the standard chamber, the HC300 features a stainless steel base and high-density plastic dome that can be fully disassembled for efficient, thorough cleaning. The removable base makes it easy to eliminate mineral scale buildup that can degrade humidifier performance over time.

The chamber holds 15.2 ounces (approximately 450-480 mL) of water and has two ports located on the top of the dome for airflow connections. It can also be used on its own as an unheated, cold, or passover humidifier without the heated base.

The kit includes the HC300 water chamber, two chamber connectors, and one 24-inch inlet tube (900HC009), providing everything needed to replace or upgrade your existing humidification chamber.

  • 1x HC300 Water Chamber (stainless steel base with plastic dome)
  • 2x Chamber Connectors
  • 1x Inlet Tube (24 inches / 61 cm)

Extended Life Construction — Built with a stainless steel base and high-density plastic dome for durable, long-lasting performance that can last several years with proper care.

Fully Disassembles for Cleaning — The base and dome separate completely, allowing thorough cleaning of all interior surfaces to remove mineral deposits and scale buildup.

15.2 oz Capacity — Holds approximately 450-480 mL of water with two ports on the dome top for airflow connections.

Versatile Use — Works with the HC100/150 heated humidifier base or can be used independently as an unheated, cold, or passover humidifier.

Complete Kit — Includes the water chamber, two chamber connectors, and a 24-inch inlet tube so you have everything needed for installation.

  • Specifications
  • Compatibility
  • Care & Safety
Specification Detail
Manufacturer Fisher & Paykel Healthcare
Part Number HC300
Capacity 15.2 oz (approximately 450–480 mL)
Ports 2 ports on top of dome
Base Material Stainless Steel
Dome Material High-Density Plastic
Included Tube 900HC009 (24″ / 61 cm)
Latex-Free Yes
Dimensions (Humidifier) 5.4 cm (H) x 13.2 cm x 14.6 cm (2.1″ x 5.2″ x 5.7″)
Warranty Manufacturer 3 months
Tax Category CPAP Replacement Supplies
Billing Code A7046 (Humidifier Chamber)

Compatible Humidifiers:

  • Fisher & Paykel HC100 Heated Humidifier
  • Fisher & Paykel HC105 Heated Humidifier
  • Fisher & Paykel HC150 Heated Humidifier
  • Fisher & Paykel H150 Heated Humidifier
  • Fisher & Paykel 900HC105 Humidification Starter Kit

Not Compatible With:

  • Fisher & Paykel SleepStyle CPAP (uses built-in humidifier)
  • ResMed AirSense 10/11 humidifiers
  • Philips DreamStation humidifiers
  • Any other brand or model humidifier

Upgrade Note: The HC300 is an upgrade from the standard HC325 disposable chamber. It provides the same functionality with longer lifespan and easier cleaning thanks to the disassemblable design and stainless steel base.

Cleaning:

  1. Disassemble the chamber by separating the stainless steel base from the dome
  2. Wash all components with warm water and mild soap
  3. For mineral scale buildup, soak in white vinegar for several hours or overnight
  4. Rinse thoroughly and air dry completely before reassembly

Important Water Guidelines:

  • Use only room temperature distilled water
  • Do not fill above the maximum fill line
  • Do not add chemicals or additives to the water
  • Do not fill the tank while inside the humidifier
  • Empty all water before transporting the humidifier

Safety Precautions:

  • Do not turn the humidifier on without the water tank installed
  • Keep the humidity setting at 0 if there is no water in the tank
  • Set the humidifier door to the open position before removing the tank
  • Do not move the humidifier while the tank contains water
  • When disconnecting the hose from the tank inlet, ensure the hose is not holding water that could flow into the machine

Why Choose the HC300 Extended Life Chamber

Built to Last Years

Stainless steel base and high-density plastic dome provide a durable, long-lasting upgrade over the standard disposable chamber. With proper care, the HC300 can last several years of nightly use.

Easy Deep Cleaning

Fully disassembles so you can access every interior surface for thorough cleaning. Remove the stainless steel base to scrub away mineral deposits and scale that degrade humidifier performance.

Complete Replacement Kit

Includes the water chamber, two connectors, and a 24-inch inlet tube. Everything you need to replace or upgrade your existing HC100/150 humidification chamber in one package.

Frequently Asked Questions

The HC300 Extended Life Humidifier Chamber is compatible with Fisher & Paykel HC100, HC105, HC150, and H150 series heated humidifiers, as well as the 900HC105 Humidification Starter Kit.

Sources differ on dishwasher safety. Some retailers state it is dishwasher safe while the CPAP.com listing states it is not. For best results and longevity, hand washing with warm water and mild soap is recommended. For mineral buildup, soak in white vinegar.

The HC300 is an upgrade with more durable construction. It features a stainless steel base and high-density plastic dome that can be fully disassembled for thorough cleaning. The standard HC325 is a disposable chamber that cannot be disassembled and needs to be replaced more frequently.

The HC300 holds 15.2 ounces (approximately 450 to 480 mL) of water. Do not fill above the maximum fill line.

Yes. The HC300 can be used on its own as an unheated, cold, or passover humidifier without the heated base unit.

Use only room temperature distilled water. Do not add any chemicals, additives, or tap water, as these can cause mineral buildup or potentially irritate your airway.

Disassemble the chamber and soak the components in white vinegar for several hours or overnight. Rinse thoroughly with clean water and air dry completely before reassembly.

The HC300 Extended Life Humidifier Chamber carries a 3-month manufacturer warranty from Fisher & Paykel Healthcare.

Reviews

Only logged in customers who have purchased this product can leave a review.

We are experts in what we do!

14+ years of sleep apnea expertise serving patients throughout the United States. Work closely with our sleep specialists to get personalized care and comfort.

You May Also Like

Prescription Policy

Federal law requires we have a valid prescription before this product can be shipped.

Don’t have a prescription? Order our Home Sleep Test to see if you qualify.

Already have a prescription? Great. You can upload it after checkout.

Need to renew your prescription? No problem, please check out prescription renewal option here.